Electronics:
|
|
display:
|
12-lines Super-Twisted-LCD-display, suitable for
graphics
|
| measuring value display: |
pressure drop in Pa, mmAQ or mbar
leak rate in Ncm³/min
test pressure in bar oder mbar
|
| keyboard: |
foil keyboard with functional keys
|
| test parameter: |
part-no., station no. and machine-no
filling, finefilling, balancing and measuring time max. 999.9
s
limit values for "Rework I", "Rework II",
"Reject" and min./ max. test pressure
"n" x "Reject"
Evacuating time 0
9 sec.
|
| write protection: |
by key-operated switch
|
| counter: |
total number of parts, OK-parts, Rework I, Rework
II and Reject
|
| fault reports: |
plain text on LCD-display with help-functions
|
| languages: |
max. number 3, switchable
|
| test programs: |
up to 99 complete test programs possible
|
| analog presentation: |
graphic illustration of filling and pressure drop
on the display
|
| statistics: |
trend analysis card and nominal distribution histogram
with alarm and intervention limit
|
| interfaces: |
1 parallel interface machine control with
16 In-/ Outputs 24 V DC
2 serial interfaces RS 232
profibus interface optional
|
Pneumatics:
|
|
| measuring methods: |
pressure drop/ rise
|
| test pressure: |
excess pressure:
0,02 ... 1 bar
0,5 ... 4 bar
0,5 ... 10 bar
0,5 ... 16 bar
vacuum:
-0,02 ... -0,9 bar
|
Construction:
|
|
| housing: |
steel sheet housing with 19" - 4 HE measurement
rack-mounting
|
| sizes: |
500 x 240 x 520 mm (WxHxD)
|
| weight: |
about 33 kg
|
| electrical supply: |
24 V DC, optional 230 V, 50 H
|
| air supply: |
5...17 bar, at min. 1 bar over test pressure |
|
|